Urinal | The Building Code Forum
Mar 27, 2024 · B occupancy restaurant. 16 males per table 422 CPC. Single occupancy men's restroom. Urinal required? Code location?
Are Urinals Required in Unisex Restrooms? | The Building Code Forum
Nov 13, 2023 · Not sure if this belongs in the plumbing code forum, but is there a specific section of code that would allow me to remove a urinal from a single user unisex toilet room? My firm and I are …
ICC ANSI - forward approach to urinal | The Building Code Forum
Oct 17, 2009 · I have another question concerning accessibility - an on site inspection by a state ran agency has stated the following code section in regards to a Men's group restroom with two urinals. …
Door on Accessible Urinal Stall | The Building Code Forum
Oct 16, 2009 · In this men’s room there are 2 water closets, and one urinal. One of the two water closets is accessible. This is in a public library. There is a 24” door to the urinal. 1) Is this urinal required to …
Is there a code definition of "compartment" (toilet or urinal)?
Nov 2, 2009 · However, due to lack of definition of "compartment" (see post #4), there are people thinking that a single accommodation toilet room (1 lav, 1 wc, 1 urinal) is a type of "compartment". If …
Bathroom stall door and partition height - The Building Code Forum
Oct 17, 2009 · urinal measured from the finished backwall surface, whichever is greater. Exceptions: 1. Urinal partitions shall not be required in a singleoccupant or family or assisted-use toilet room with a …
Urinal required in a single occupancy toilet for "B" occupancy?
Aug 16, 2011 · We have a plan checker that is insisting that because the California Plumbing Code table 422.1 indicates that a urinal is required for 1-100 men for a B occupancy that even when a single …
Non-ADA Toilet Stall Dimensions - The Building Code Forum
Jan 18, 2016 · A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction, or closer than 30 inches (762 …
1, single user, unisex toilet room in coffee shop, per 2021 IBC
Feb 24, 2025 · In such multiple-user user facilities, each fixture type shall be in accordance with ICC A117.1 and each urinal that is provided shall be located in a stall. 3.Distribution of the sexes is not …
Urinal flushometer [Vacuum Breaker] | The Building Code Forum
Jan 6, 2013 · Re: Urinal flushometer [Vacuum Breaker] Thanks for the replies. It's a solid slab of granite on the wall, so the only real option would be to go back to the original urinal as opposed to raising …