Single phase 400 amp service w/2 200amp disconnects
Apr 6, 2023 · On a recent installation of a single phase 400 amp with standard ringless meter base going to two. 200A disconnects each going to 200 amp main lug panels. The state inspector filled it, …
What wire for underground service to 400 amp meter base
Apr 18, 2023 · This would then feed two 200 amp panels (probably outside so I have the two service disconnects outside). POCO says we're responsible for the wire from the transformer to the meter …
Expert Answers on 320/400 Amp Meter Bases | JustAnswer Electrical
A PG&E approved 320/400 amp meter base with two separate 200 amp 2-pole breakers must meet utility specifications. Milbank and Square D are common brands but tend to be costly locally.
Properly configuring layout for 400 A service/meter socket with 3 ...
Apr 10, 2023 · If I use a 400 A fusible disconnect immediately on the interior wall from the 400 A meter socket, what is the best way to get from the fusible disconnect to the 3 feeds, one for each sub …
Feeding 2 panels from one source | Information by Electrical ...
Jun 24, 2021 · this is for a single family residential home. single phase, 120/240v. upgrading service to 400 amp. Due to layout, panels can not be near meter location so we will need to install a disconnect …
400 amp service, 2 parallel feeds, 2 or 1 neutral going back to ...
Jan 9, 2025 · On a 400 amp meter main service, I used two 4/0 aluminum parallel feeds for my hot conductors, from transformer to meter base. (i have to supply my own wire on a 400 amp service …
400a split (parallel) service - Mike Holt's Forum
May 27, 2021 · What they have is a 400 (320) meter base with a 400a non-fused disconnect fed with parallel 3/0s from meter to line side. From the load side of the disconnect, they did 2/0 cu to a 200a …
400 Amp Service - Residential | Information by Electrical Professionals ...
Dec 15, 2023 · I’m about to do this 400 amp service for a single family home. Can I run what I’m going to do by you. 1. I was going to run three 600 al XHHW underground outside. 2. I’m going to install a …
At what Amp level is the CT cabinet for meter required
Apr 19, 2021 · They do make 400 amp and 800 CT and meter cabinets in one enclosure with a 10 point meter. It would be up to the local POCO to decide what they will allow you the use. The one on the …
400 amp service is only 320 amps ? | Information by Electrical ...
Feb 3, 2025 · A lever bypass meter socket for a residential service is rated for 320 amps continuous duty and is the largest single phase meter that our local PoCo will allow without a CT cabinet. I have …